Our project

3T High-Res Neuro Coil

ID Coil’s in-house developed 3T High-Resolution Neuro Coil marks a significant advancement in MRI technology.

Engineers working on the 3T High-Res Neuro Coil
We make it possible

Unmatched imaging resolution and quality

Tailored for imaging the head, neck, and spine, especially for MS patients, this innovative coil enables comprehensive scans in under an hour.

With unmatched imaging resolution and quality, it enables healthcare professionals to obtain detailed, high-resolution images of these critical areas, streamlining the diagnostic process and ultimately enhancing patient care. This project highlights ID Coil’s commitment to pushing the boundaries of MR technology to achieve better healthcare outcomes.

16Receive channels (interface box)
7–10%Enhancement in SNR
Phase 1 – Interface box

Crossing a significant milestone

The 3T High-Res Neuro Coil has reached a significant milestone with the successful completion and approval of its proof of concept. The next phase involves constructing six pre-production models for rigorous reliability testing at three customer sites. Additionally, the design of the 3T digital interface box, tailored for Philips MRI systems, has been finalized and is now ready for prototyping. This progress underscores ID Coil’s dedication to advancing MRI technology.

Proof of conceptProof of concept completed and approved.
Design3T digital interface box, designed for Philips MRI.
PrototypingFirst prototypes are developed.
3T digital interface box
The benefits

Interface box

01

Channels

The 3T High-Res Neuro Coil interface box has 16 receiving channels.

02

Signal-to-noise ratio

7–10% enhancement in signal-to-noise ratio (SNR) when used in conjunction with standard receive coils.

03

Stability

Exhibited improved stability compared to the original Philips interface box, further validating its effectiveness.

04

Signal-to-noise ratio

The SNR of our interface box surpasses the performance of six standard customer interface boxes.

Diagram: RF signal processing from patient to MR system
Phase 2 – The coil

Testing without an MR system

A specialized test tool was developed to measure the 3D RF field, enabling performance testing of the 3T High-Res Neuro Coil without requiring an MR system.

This innovation accelerates the development process by enabling more efficient and precise evaluations. Several design iterations have been defined for the upcoming prototyping phase to ensure optimal performance and reliability.

Learn more about our 3D RF Near-Field Scanning Tool
Phase 3 – Combining

Optimal SNR in the region of interest

The development of the 3T High-Res Neuro Coil follows a meticulous approach, combining stages 1 and 2 to achieve an optimal signal-to-noise ratio (SNR) within the region of interest (ROI).

This dual-stage strategy underscores our commitment to quality, safety, user-friendliness, and patient comfort, ensuring a superior imaging experience.

Engineer testing a coil element
Engineer at the measurement bench
Phase 4 – Prototyping & testing

Preparing for production

The 3T High-Res Neuro Coil project is advancing rapidly, with pre-production models ready for rigorous testing.

As part of our commitment to quality and compliance, we are actively pursuing CE marking and FDA approval, having already implemented the required business processes. We have completed our ISO 9001 certification and are now ready for ISO 13485 certification when needed in the future. With these milestones in place, we are preparing for the production of the high-resolution neuro coil, reaffirming our dedication to excellence.

This groundbreaking project is made possible thanks to a subsidy from the Province of North Brabant, provided through the “Innovation of existing SME companies” scheme.

Provincie Noord-Brabant